W DOC AIRBUS | AMM A320F

Removal of the Contactors


TASK 24-42-55-000-001-A
Removal of the Contactors


WARNING: MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS. THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
ZONE: 212
FIN: 12XX
FIN: 14XX
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
212
COCKPIT
121AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-58-000-001-A
Removal of the AC Service Bus Contactor Module
TASK 25-11-41-000-001-A
Removal of the Third Occupant Seat
F Contactors ** ON A/C NOT FOR ALL
F Contactors ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 24-42-55-010-050-A
A. Get Access
   (1) Remove the Third Occupant seat (Ref. AMM TASK 25-11-41-000-001).
   (2) Remove the front panel of the AC power center 123VU.
   (3) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position at the access door 121AL.
   (4) Open the access door 121AL.
Subtask 24-42-55-941-050-A
B. Safety Precautions
   (1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
   (2) Put WARNING NOTICE(S) in position on the access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.
   (3) In the cockpit, on the ELEC panel 35VU, make sure that these pushbutton switches are released:
  • BAT 1, BAT 2,
  • APU GEN,
  • GEN 1, GEN 2,
  • EXT PWR.
   (4) In the cockpit, put WARNING NOTICE(S) in position to tell persons not to operate the pushbutton switches on these overhead panels:
  • 21VU (EMER ELEC PWR section),
  • 25VU (APU section),
  • 35VU (ELEC).
Subtask 24-42-55-865-050-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUELEC/EXT PWR/LT CLT/NOT IN/USE6XGX30
4. Procedure
Subtask 24-42-55-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Contactor
CAUTION: REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
   (1) Disconnect the electrical connector (10).
   (2) Put blanking caps on the disconnected electrical connector (10) and the electrical receptacle (9).
   (3) Loosen the captive screws (8).
NOTE: Do not remove the captive screws (8) and the spring washers from the contactor (11).
   (4) Remove the contactor (11).
Subtask 24-42-55-020-052-A ** ON A/C NOT FOR ALL
CAUTION: MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
B. Removal of the Contactor Base
NOTE: The removal of the contactor base is necessary only if it is damaged.
   (1) Remove the nuts (7) and the washers (6).
   (2) Disconnect the cables (5) from the contactor base (1).
   (3) Remove the nuts (12) and the washers (13).
   (4) Remove the jumper (14) from the contactor base (1) and from the adjacent contactor base.
   (5) Remove the screws (4) and the washers (3).
   (6) Remove the contactor base (1).
Subtask 24-42-55-020-050-B ** ON A/C NOT FOR ALL
C. Removal of the Contactor
CAUTION: REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
   (1) Disconnect the electrical connector (1).
   (2) Put blanking caps on the disconnected electrical connector (1) and the electrical receptacle.
   (3) Loosen the captive screws (2).
NOTE: Do not remove the captive screws (2) and the spring washers from the contactor (3).
   (4) Remove the contactor (3).
Subtask 24-42-55-020-052-B ** ON A/C NOT FOR ALL
D. Removal of the Module 20XX
NOTE: The removal of the module is necessary only if it is damaged.
   (1) Remove the module 20XX (Ref. AMM TASK 24-42-58-000-001).
[Rev.10 from 2021] 2026.04.01 05:51:37 UTC