Installation of the Pack-Outlet Pneumatic Sensor


TASK 21-61-19-400-002-A
Installation of the Pack-Outlet Pneumatic Sensor


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
NOTE: The procedure is the same for pack-outlet pneumatic sensors 10HM10 and 11HM10.
FIN: 10HM10 ** ON A/C NOT FOR ALL
FIN: 11HM10 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
Torque wrench: range to between 0.915 and 0.9 m.daN (80.97 and 79.65 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03FAB1)
Mineral Oil base Grease-- Vaseline or Petrolatum -
(Material No.14QDB1)
Wire-Locking Dia: 0.5 mm (0.020 inch) CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB
FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
5
PACKING
AIPC 21-52-41-26-100
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-33-21-618-001-A-01
Pre-conditioning through the HP Ground Connection
TASK 12-33-21-618-001-A-02
Pre-conditioning with the APU
TASK 21-61-00-710-001-A
Operational Test of the Pack Temperature-Control System
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
TASK 53-35-13-400-002-A
Installation of the Quick-Release Access Panels on the Belly Fairing Structure
3. Job Set-up
Subtask 21-61-19-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical ciruits are energized (Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the access panel is removed (Ref. AMM TASK 53-35-13-000-002).
     (a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
     (b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB.
Subtask 21-61-19-865-054-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 10HM10 (SENSORPACK OUTLET PNEUMATIC)
49VUAIR COND/FLOW/CTL &/IND11HBD07
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
FOR FIN: 11HM10 (SENSORPACK OUTLET PNEUMATIC)
122VUAIR COND/FLOW/CTL AND IND/22HBV21
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
4. Procedure
Subtask 21-61-19-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Pack-Outlet Pneumatic Sensor
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Make sure that the removed packing (5) is in a good condition. If necessary replace the AIPC 21-52-41-26-100 PACKING (5).
   (3) Remove the blanking plugs from the disconnected line ends.
   (4) Clean the component interfaces and the adjacent area.
   (5) Apply a small quantity of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.
03FAB1) to the screws (1).
   (6) Put the packing (5) in position on the pack-outlet pneumatic sensor (4).
   (7) Put the pack-outlet pneumatic sensor (4) in position in the condensor (6) and install the washers (2) and the screws (1).
   (8) Make sure that the pack-outlet pneumatic sensor (4) is in the correct position and tighten the screws (1).
   (9) Wipe clean the excess Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) from the screws (1) and safety with 14QDB1Wire-Locking Dia: 0.5 mm (0.020 inch) CRES Nickel Alloy -.
   (10) Connect the sense line (3).
   (11) TORQUE the sense line (3) connector to between 0.915 and 0.9 m.daN (80.97 and 79.65 lbf.in ) T.
Subtask 21-61-19-865-055-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 10HM10 (SENSORPACK OUTLET PNEUMATIC)
49VUAIR COND/FLOW/CTL &/IND11HBD07
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
FOR FIN: 11HM10 (SENSORPACK OUTLET PNEUMATIC)
122VUAIR COND/FLOW/CTL AND IND/22HBV21
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
Subtask 21-61-19-710-050-A ** ON A/C NOT FOR ALL
C. Test
   (1) Do the pre-conditioning through the HP ground connector or with the APU (
Ref. AMM TASK 12-33-21-618-001) (Ref. AMM TASK 12-33-21-618-001).
   (2) Do a leak check of the pack-outlet pneumatic sensor sense line connection.
NOTE: Leaks are not permitted.
   (3) After approx. 15 minutes stop the pre-conditioning (Ref. AMM TASK 12-33-21-618-001) (Ref. AMM TASK 12-33-21-618-001).
   (4) Do the operational test of the pack temperature control system (Ref. AMM TASK 21-61-00-710-001).
5. Close-up
Subtask 21-61-19-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel (Ref. AMM TASK 53-35-13-400-002).
     (a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
     (b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB
Subtask 21-61-19-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).