Installation of the Pack-Outlet Pneumatic Sensor
TASK 21-61-19-400-002-A
Installation of the Pack-Outlet Pneumatic Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 21-61-19-860-050-A ** ON A/C NOT FOR ALL
Subtask 21-61-19-420-050-A ** ON A/C NOT FOR ALL
Subtask 21-61-19-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.05 10:34:33 UTC
Installation of the Pack-Outlet Pneumatic Sensor
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
NOTE: The procedure is the same for pack-outlet pneumatic sensors 10HM10 and 11HM10.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | Torque wrench: range to between 0.915 and 0.9 m.daN (80.97 and 79.65 lbf.in ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03FAB1) | Mineral Oil base Grease-- Vaseline or Petrolatum - |
| (Material No.14QDB1) | Wire-Locking Dia: 0.5 mm (0.020 inch) CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC) | |
| 191BB | |
| FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC) | |
| 192FB | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 5 | PACKING | AIPC 21-52-41-26-100 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-33-21-618-001-A-01 | Pre-conditioning through the HP Ground Connection |
| TASK 12-33-21-618-001-A-02 | Pre-conditioning with the APU |
| TASK 21-61-00-710-001-A | Operational Test of the Pack Temperature-Control System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 53-35-13-000-002-A | Removal of the Quick-Release Access Panels from the Belly Fairing Structure |
| TASK 53-35-13-400-002-A | Installation of the Quick-Release Access Panels on the Belly Fairing Structure |
Subtask 21-61-19-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical ciruits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the access panel is removed (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
(b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB.
Subtask 21-61-19-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical ciruits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the access panel is removed (Ref. AMM TASK 53-35-13-000-002).
(a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
(b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM10 (SENSORPACK OUTLET PNEUMATIC) | |||
| 49VU | AIR COND/FLOW/CTL &/IND1 | 1HB | D07 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| FOR FIN: 11HM10 (SENSORPACK OUTLET PNEUMATIC) | |||
| 122VU | AIR COND/FLOW/CTL AND IND/2 | 2HB | V21 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
Subtask 21-61-19-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Pack-Outlet Pneumatic Sensor
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Make sure that the removed packing (5) is in a good condition. If necessary replace the AIPC 21-52-41-26-100 PACKING (5).
(3) Remove the blanking plugs from the disconnected line ends.
(4) Clean the component interfaces and the adjacent area.
(5) Apply a small quantity of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) to the screws (1).
(6) Put the packing (5) in position on the pack-outlet pneumatic sensor (4).
(7) Put the pack-outlet pneumatic sensor (4) in position in the condensor (6) and install the washers (2) and the screws (1).
(8) Make sure that the pack-outlet pneumatic sensor (4) is in the correct position and tighten the screws (1).
(9) Wipe clean the excess Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) from the screws (1) and safety with14QDB1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES Nickel Alloy - .
(10) Connect the sense line (3).
(11) TORQUE the sense line (3) connector to between 0.915 and 0.9 m.daN (80.97 and 79.65 lbf.in )
.
Subtask 21-61-19-865-055-A ** ON A/C NOT FOR ALL (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Make sure that the removed packing (5) is in a good condition. If necessary replace the AIPC 21-52-41-26-100 PACKING (5).
(3) Remove the blanking plugs from the disconnected line ends.
(4) Clean the component interfaces and the adjacent area.
(5) Apply a small quantity of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) to the screws (1).
(6) Put the packing (5) in position on the pack-outlet pneumatic sensor (4).
(7) Put the pack-outlet pneumatic sensor (4) in position in the condensor (6) and install the washers (2) and the screws (1).
(8) Make sure that the pack-outlet pneumatic sensor (4) is in the correct position and tighten the screws (1).
(9) Wipe clean the excess Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) from the screws (1) and safety with
(10) Connect the sense line (3).
(11) TORQUE the sense line (3) connector to between 0.915 and 0.9 m.daN (80.97 and 79.65 lbf.in )
. B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-61-19-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 10HM10 (SENSORPACK OUTLET PNEUMATIC) | |||
| 49VU | AIR COND/FLOW/CTL &/IND1 | 1HB | D07 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| FOR FIN: 11HM10 (SENSORPACK OUTLET PNEUMATIC) | |||
| 122VU | AIR COND/FLOW/CTL AND IND/2 | 2HB | V21 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
C. Test
(1) Do the pre-conditioning through the HP ground connector or with the APU (Ref. AMM TASK 12-33-21-618-001) (Ref. AMM TASK 12-33-21-618-001).
(2) Do a leak check of the pack-outlet pneumatic sensor sense line connection.
(4) Do the operational test of the pack temperature control system (Ref. AMM TASK 21-61-00-710-001).
5. Close-up(1) Do the pre-conditioning through the HP ground connector or with the APU (Ref. AMM TASK 12-33-21-618-001) (Ref. AMM TASK 12-33-21-618-001).
(2) Do a leak check of the pack-outlet pneumatic sensor sense line connection.
NOTE: Leaks are not permitted.
(3) After approx. 15 minutes stop the pre-conditioning (Ref. AMM TASK 12-33-21-618-001) (Ref. AMM TASK 12-33-21-618-001). (4) Do the operational test of the pack temperature control system (Ref. AMM TASK 21-61-00-710-001).
Subtask 21-61-19-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
(b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB
Subtask 21-61-19-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel (Ref. AMM TASK 53-35-13-400-002).
(a) FOR [10HM10] (SENSOR-PACK OUTLET PNEUMATIC)
191BB.
(b) FOR [11HM10] (SENSOR-PACK OUTLET PNEUMATIC)
192FB
Pack Outlet Pneumatic-Sensor