Removal of the Mixer Flap Actuator
TASK 21-51-52-000-001-A
Removal of the Mixer Flap Actuator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-51-52-861-051-A Subtask 21-51-52-865-050-A
Subtask 21-51-52-020-050-A
[Rev.10 from 2021]
2026.04.05 10:34:31 UTC
Removal of the Mixer Flap Actuator
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
FIN: 20HB
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 131NW, 131PW, 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 25-54-12-000-001-A | Removal of the Forward Cargo-Compartment Partition |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 21-51-52-861-051-A Subtask 21-51-52-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-51-52-941-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/FLOW/MIXER/FLAP | 3HB | V22 |
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS2 | 4HK | V20 |
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS1 | 3HK | V19 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS2 | 2HK | V18 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS1 | 1HK | V17 |
| ** ON A/C ALL | |||
| 122VU | AIR COND/RECIRC FAN/R/CTL | 11HG | W20 |
| 122VU | AIR COND/RECIRC FAN/R/SPLY | 3HG | W18 |
| 122VU | AIR COND/RECIRC FAN/L/CTL | 2HG | X20 |
| 122VU | AIR COND/RECIRC FAN/L/SPLY | 1HG | X18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
C. Safety Precautions
(1) On the overhead panel, on AIR COND panel 30VU:
(a) Make sure that:
(2) On the HP and the LP ground connectors, put a WARNING NOTICE(S) in position to tell persons not to supply the ground air.
Subtask 21-51-52-010-050-A (1) On the overhead panel, on AIR COND panel 30VU:
(a) Make sure that:
- The APU BLEED pushbutton switch is released (the ON legend is off).
- The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are released (the OFF legends are on).
(2) On the HP and the LP ground connectors, put a WARNING NOTICE(S) in position to tell persons not to supply the ground air.
D. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the forward cargo-compartment door 825.
(3) Remove access panels 131PW and 131NW (Ref. AMM TASK 25-54-12-000-001).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the forward cargo-compartment door 825.
WARNING:
DO NOT OPEN OR GO NEAR PRESSURE-SEALED DOORS WHEN THE AIRCRAFT IS PRESSURIZED.
A PRESSURE-SEALED DOOR THAT OPENS WHEN THE AIRCRAFT IS PRESSURIZED:
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001). - WILL CAUSE EXPLOSIVE DECOMPRESSION.
- CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAUSE DAMAGE TO THE AIRCRAFT OR EQUIPMENT.
(3) Remove access panels 131PW and 131NW (Ref. AMM TASK 25-54-12-000-001).
Subtask 21-51-52-020-050-A
A. Removal of the Mixer Flap Actuator
(1) Disconnect the electrical connector (3).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the clamp (8) and disconnect the sleeve (7).
(4) Remove the nuts (13), the washers (12) and the bolts (10).
(5) Carefully remove the mixer-flap actuator housing (9) and the seal (11).
(6) Remove the bolts (4), the washers (5) and the mixer flap actuator (6).
(7) Put protective covers on the open ends of the sleeve (7), the mixer unit (14) and the mixer-flap actuator housing (9).
(1) Disconnect the electrical connector (3).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the clamp (8) and disconnect the sleeve (7).
(4) Remove the nuts (13), the washers (12) and the bolts (10).
(5) Carefully remove the mixer-flap actuator housing (9) and the seal (11).
(6) Remove the bolts (4), the washers (5) and the mixer flap actuator (6).
(7) Put protective covers on the open ends of the sleeve (7), the mixer unit (14) and the mixer-flap actuator housing (9).
Mixer Unit-Flap Actuator