W DOC AIRBUS | AMM A320F

Cold Weather Maintenance - Indicating/Recording systems and Navigation


TASK 12-31-31-660-001-A
Cold Weather Maintenance - Indicating/Recording systems and Navigation


ZONE: 120
1. Reason for the Job
This procedure gives the cold weather maintenance practices for the indicating/recording and navigation systems.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 12-31-21-660-001-A
Cold Weather Maintenance - Air Conditioning
3. Job Set-up
Subtask 12-31-31-941-050-A
A. Not Applicable
4. Procedure
Subtask 12-31-31-660-050-A
A. General.
   (1) When the Outside Air Temperature (OAT) is very low, cold (temperature lower than -15 deg.C (5.00 deg.F)) in the avionics compartment can cause incorrect operation of the computers.
NOTE: This is only due to the cold weather conditions and not to a technical malfunction.
Subtask 12-31-31-660-051-A
B. Recommendations.
   (1) Make sure that the computers are at a temperature equal to or higher than -15 deg.C (5.00 deg.F) for correct operation.
NOTE: If you energize the computers at very low temperatures the following can occur. If the temperature is :
  • equal to or lower than -40 deg.C (-40.00 deg.F), you can cause permanent damage to the computers.
  • between -40 deg.C (-40.00 deg.F) and -15 deg.C (5.00 deg.F), the computers can operate but normal operation can stop momentarily.
  • equal to or higher than -15 deg.C (5.00 deg.F), the computers operate normally.
     (a) Preconditioning
It is recommended to use the pre-conditioning procedure to increase the temperature in the avionics compartment (Ref. AMM TASK 12-31-21-660-001).
     (b) Energization of the computers
If the temperature is higher than -40 deg.C (-40.00 deg.F), you can energize the computers to increase the temperature to -15 deg.C (5.00 deg.F). The time necessary to increase the temperature will change with the OAT, the humidity and the time since the avionics compartment ventilation stopped.
Subtask 12-31-31-660-052-A ** ON A/C NOT FOR ALL
C. Recommendations for the Flight Data Interface and Management Unit (FDIMU) (10TV) with SPC (10TV4) installed
   (1) Make sure that the FDIMU is at a temperature equal to or higher than -15 deg.C (5.00 deg.F) for correct operation.
     (a) If the temperature in the avionics compartment is less than -15 deg.C (5.00 deg.F):
  • The Smart PCMCIA Card (SPC) installed on the FDIMU can become unserviceable.
  • The DMU FAIL LED on the front face of the FDIMU can come on.
  • It is impossible to write ACMS data on the SPC flash memory.
     (b) Preconditioning
It is recommended to use the pre-conditioning procedure to increase the temperature in the avionics compartment (Ref. AMM TASK 12-31-21-660-001).
     (c) Restart the FDIMU
When the temperature in the avionic compartment is equal to or higher than -15 deg.C (5.00 deg.F), on panel 121VU, open and close the circuit breaker 5TV to restart the FDIMU.