W DOC AIRBUS | AMM A320F

General Visual Inspection of FWD Passenger/Crew Doors including Door Stops on Fuselage Door Frame and Door Seals, External Surface (EWIS)


TASK 05-28-30-200-807-A
General Visual Inspection of FWD Passenger/Crew Doors including Door Stops on Fuselage Door Frame and Door Seals, External Surface (EWIS)


ZONE: 831
ZONE: 841
1. Reason for the Job
Refer to the MPD TASK: ZL-831-04
GENERAL VISUAL INSPECTION OF FWD PASSENGER/CREW DOORS INCLUDING DOOR STOPS ON FUSELAGE DOOR FRAME AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
NOTE: This inspection procedure is not applicable for deactivated passenger/crew doors.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
831
FORWARD PASSENGER/CREW DOOR
841
FORWARD PASSENGER/CREW DOOR
831, 841
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
TASK 52-10-00-410-001-A
Closing of the Passenger/Crew Door
3. Job Set-up
Subtask 05-28-30-010-068-A
A. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 831 (841).
   (2) Open forward passenger/crew door 831 ( 841) (Ref. AMM TASK 52-10-00-010-001).
4. Procedure
Subtask 05-28-30-210-073-A
A. Inspection
   (1) Do a general visual inspection of the forward passenger/crew doors. This inspection includes the door stops on the fuselage door frames, the door seals and the external surface of the doors.
   (2) Make sure that there are no signs of corrosion, cracks or damage.
   (3) Make sure that all the installations are attached correctly.
5. Close-up
Subtask 05-28-30-410-068-A
A. Close Access
   (1) Close forward passenger/crew door 831 ( 841) (Ref. AMM TASK 52-10-00-410-001).
   (2) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 22:51:06 UTC