GENERAL VISUAL INSPECTION OF FWD AND AFT EMERGENCY EXITS - EXTERNAL SKIN (EWIS)
TASK 05-28-30-200-009-A
GENERAL VISUAL INSPECTION OF FWD AND AFT EMERGENCY EXITS - EXTERNAL SKIN (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-833-03
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
3. Job Set-up
Subtask 05-28-30-941-050-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-210-058-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-942-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2017]
2026.03.31 22:51:10 UTC
GENERAL VISUAL INSPECTION OF FWD AND AFT EMERGENCY EXITS - EXTERNAL SKIN (EWIS)
1. Reason for the Job
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 833 | EMERGENCY EXITS |
| 834 | EMERGENCY EXITS |
| 843 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
Subtask 05-28-30-941-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zones 833(843) and 834(844).
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zones 833(843) and 834(844).
Subtask 05-28-30-210-058-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a general visual inspection of the external skin of the forward and aft emergency exits (Zones 833(843) and 834(844)).
(2) Make sure that there are no signs of corrosion, cracks or damage.
5. Close-up(1) Do a general visual inspection of the external skin of the forward and aft emergency exits (Zones 833(843) and 834(844)).
(2) Make sure that there are no signs of corrosion, cracks or damage.
Subtask 05-28-30-942-050-A ** ON A/C NOT FOR ALL
A. Close Access
Remove the access platform(s).
Remove the access platform(s).