General Visual Inspection of Powerplants, Nacelles and Pylons
TASK 05-24-00-200-002-A
General Visual Inspection of Powerplants, Nacelles and Pylons
Refer to the MPD TASK: ZL-400-02
GENERAL VISUAL INSPECTION OF POWERPLANTS, NACELLES AND PYLONS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-24-00-010-051-A
Subtask 05-24-00-210-051-A
Subtask 05-24-00-410-051-A
[Rev.10 from 2021]
2026.03.31 22:49:48 UTC
General Visual Inspection of Powerplants, Nacelles and Pylons
WARNING:
MAKE SURE THAT THE SAFETY DEVICES AND THE WARNING NOTICES ARE IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND RELATED DOORS
- THE CARGO DOORS
- THE ENGINES
- OTHER COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
ZONE: 400
1. Reason for the JobRefer to the MPD TASK: ZL-400-02
GENERAL VISUAL INSPECTION OF POWERPLANTS, NACELLES AND PYLONS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 05-24-00-010-051-A
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at zone 400.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at zone 400.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(2) Put on and attach a safety harness before you start work in the work area.Subtask 05-24-00-210-051-A
A. Inspection
Powerplants, Nacelles and Pylons ** ON A/C NOT FOR ALL
Powerplants, Nacelles and Pylons ** ON A/C NOT FOR ALL
Powerplants, Nacelles and Pylons ** ON A/C NOT FOR ALL
(1) Do a general visual inspection of the powerplants, the nacelles and the pylons (zone 400).
(2) Make sure that there is no deterioration (damage, corrosion, leakage, cracks or chafing).
5. Close-up
Powerplants, Nacelles and Pylons ** ON A/C NOT FOR ALL
Powerplants, Nacelles and Pylons ** ON A/C NOT FOR ALL
Powerplants, Nacelles and Pylons ** ON A/C NOT FOR ALL (2) Make sure that there is no deterioration (damage, corrosion, leakage, cracks or chafing).
Subtask 05-24-00-410-051-A
A. Close Access
(1) Remove the access platform(s).
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.
(1) Remove the access platform(s).
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.