W DOC AIRBUS | AMM A320F

GENERAL VISUAL INSPECTION OF BULK CARGO COMPARTMENT (AS FAR AS VISIBLE, IF ACT IS INSTALLED) (EWIS)


TASK 05-21-60-200-001-A
GENERAL VISUAL INSPECTION OF BULK CARGO COMPARTMENT (AS FAR AS VISIBLE, IF ACT IS INSTALLED) (EWIS)


ZONE: 161
ZONE: 162
1. Reason for the Job
Refer to the MPD TASK: ZL-161-01
GENERAL VISUAL INSPECTION OF BULK CARGO COMPARTMENT (AS FAR AS VISIBLE, IF ACT IS INSTALLED) (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
161
BULK CARGO COMPARTMENT
162
BULK CARGO COMPARTMENT
826
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 05-21-60-010-050-B
A. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 152.
   (2) Open aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
4. Procedure
Subtask 05-21-60-210-050-B
A. Inspection
   (1) Do a general visual inspection of the bulk cargo compartment (as far as visible, if the ACT is installed).
   (2) Make sure that there are no signs of corrosion, cracks or damage.
5. Close-up
Subtask 05-21-60-410-050-B
A. Close Access
   (1) Close aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
   (2) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 22:48:54 UTC