GENERAL VISUAL INSPECTION OF AVIONICS COMPARTMENT (EWIS)
TASK 05-21-20-200-001-A
GENERAL VISUAL INSPECTION OF AVIONICS COMPARTMENT (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-121-01
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
3. Job Set-up
Subtask 05-21-20-010-050-A
Subtask 05-21-20-210-050-A
Subtask 05-21-20-410-050-A
[Rev.8 from Aug 2017]
2026.03.31 22:48:35 UTC
GENERAL VISUAL INSPECTION OF AVIONICS COMPARTMENT (EWIS)
1. Reason for the Job
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| 811 |
Subtask 05-21-20-010-050-A
A. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zones 121 and 122.
(2) Open the avionic-compartment access door 811.
4. Procedure(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zones 121 and 122.
(2) Open the avionic-compartment access door 811.
Subtask 05-21-20-210-050-A
A. Inspection
(1) Do a general visual inspection of the forward avionic compartment (Zones 121 and 122).
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
5. Close-up(1) Do a general visual inspection of the forward avionic compartment (Zones 121 and 122).
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
Subtask 05-21-20-410-050-A
A. Close Access
(1) Close the avionic-compartment access door 811.
(2) Remove the access platform(s).
(1) Close the avionic-compartment access door 811.
(2) Remove the access platform(s).