W DOC AIRBUS | AMM A320F

GENERAL VISUAL INSPECTION OF RADOME (EWIS)


TASK 05-21-10-200-001-A
GENERAL VISUAL INSPECTION OF RADOME (EWIS)


ZONE: 110
1. Reason for the Job
Refer to the MPD TASK: ZL-110-01
GENERAL VISUAL INSPECTION OF RADOME (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
110
RADOME (NOSE CONE TO FR 1)
110AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 53-15-11-010-001-A
Opening of the Radome
TASK 53-15-11-410-001-A
Closing of the Radome
3. Job Set-up
Subtask 05-21-10-010-050-A
A. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zone 110.
   (2) Open the radome 110AL, (Ref. AMM TASK 53-15-11-010-001).
NOTE: Two persons are necessary to open the radome.
4. Procedure
Subtask 05-21-10-210-050-A
A. Inspection
   (1) Do a general visual inspection of the structure of the radome.
   (2) Make sure that there are no signs of corrosions, cracks or damage.
   (3) Make sure that all the installations (wiring, equipment) are attached correctly.
5. Close-up
Subtask 05-21-10-410-050-A
A. Close Access
   (1) Close the radome 110AL, (Ref. AMM TASK 53-15-11-410-001).
NOTE: Two persons are necessary to close the radome.
   (2) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 22:48:28 UTC