GENERAL VISUAL INSPECTION OF RADOME (EWIS)
TASK 05-21-10-200-001-A
GENERAL VISUAL INSPECTION OF RADOME (EWIS)
Refer to the MPD TASK: ZL-110-01
GENERAL VISUAL INSPECTION OF RADOME (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-21-10-010-050-A
Subtask 05-21-10-210-050-A
Subtask 05-21-10-410-050-A
[Rev.10 from 2021]
2026.03.31 22:48:28 UTC
GENERAL VISUAL INSPECTION OF RADOME (EWIS)
ZONE: 110
1. Reason for the JobRefer to the MPD TASK: ZL-110-01
GENERAL VISUAL INSPECTION OF RADOME (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 110 | RADOME (NOSE CONE TO FR 1) |
| 110AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 53-15-11-010-001-A | Opening of the Radome |
| TASK 53-15-11-410-001-A | Closing of the Radome |
Subtask 05-21-10-010-050-A
A. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zone 110.
(2) Open the radome 110AL, (Ref. AMM TASK 53-15-11-010-001).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the zone 110.
(2) Open the radome 110AL, (Ref. AMM TASK 53-15-11-010-001).
NOTE: Two persons are necessary to open the radome.
Subtask 05-21-10-210-050-A
A. Inspection
(1) Do a general visual inspection of the structure of the radome.
(2) Make sure that there are no signs of corrosions, cracks or damage.
(3) Make sure that all the installations (wiring, equipment) are attached correctly.
5. Close-up(1) Do a general visual inspection of the structure of the radome.
(2) Make sure that there are no signs of corrosions, cracks or damage.
(3) Make sure that all the installations (wiring, equipment) are attached correctly.
Subtask 05-21-10-410-050-A
A. Close Access
(1) Close the radome 110AL, (Ref. AMM TASK 53-15-11-410-001).
(1) Close the radome 110AL, (Ref. AMM TASK 53-15-11-410-001).
NOTE: Two persons are necessary to close the radome.
(2) Remove the access platform(s).