W DOC AIRBUS | TSM A320F

SLATS ELECTRICAL CONTROL AND MONITORING - TASK SUPPORTING DATA


** ON A/C NOT FOR ALL
1. TABLE 1
A. X-LINK DATA DISPLAY
(1) When on the submenu pages SYSTEM DATA FLAP or SLAT, the Line Key "1R" "X LINK INPUT>" is pressed, the nominated SFCC transmits the following page to the CFDS.
|-------------------------------------|
| SFCC- X |
| X-LINK INPUT DATA |
1L | BIT No. | 1R
| 9 15 21 27 32 |
2L | | 2R
| LABEL 23 |
3L | xxxxxxxxxxx = no data = xxxxxxxxxx | 3R
| LABEL 60 |
4L | 1 0 1 0 1 0 = faulty data = 1 0 1 0 | 4R
| LABEL 61 |
5L | 1 0 1 0 1 0 = faulty data = 1 0 1 0 | 5R
| |
6L | <RETURN PRINT> |
|-------------------------------------|

(2) LABEL 23 is transmitted as xxxxx- for no data.
(3) LABEL 60 is transmitted as 1 and 0 ( no parity bit ) for faulty data.
(4) LABEL 61 is transmitted as 1 and 0 ( no parity bit ) for faulty data.
B. LABELS 023, 060, 061, 062, 063, 064 etc.
(1) For detailed information of these labels, refer to TSM 27-51-00 PB 301 TABLE 1.
** ON A/C NOT FOR ALL
2. TABLE 2
A. PPU DATA DISPLAY
(1) When on the submenu pages SYSTEM DATA FLAP, the Line Key "1L" "PPU " is pressed, the named SFCC transmits the following page to the CFDS.
!\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\!
! SFCC- X !
! PPU DATA (DEG) !
1L ! DATE: UTC: ! 1R
! LH APPU FPPU RH APPU !
2L ! XXX.X XXX.X XXX.X ! 2R
! ***HEX ***HEX ***HEX !
3L ! ! 3R
! OTHER SFCC !
4L ! LH APPU FPPU RH APPU ! 4R
! XXX.X XXX.X XXX.X !
5l ! ***HEX ***HEX ***HEX ! 5R
! !
6l ! <RETURN PRINT> !
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

(2) The XXX.X fields are replaced with the decimal value of the synchro angle.
(3) The *** fields are replaced with the hexadecimal value of the synchro angle.
(4) If no data is available then the decimal value is replaced with XXX.X.
** ON A/C NOT FOR ALL
3. TABLE 3
A. Slat Operating System
(1) Mechanical and Electronic Interface Data.
-------------------------------------------------------------------------------
CONTROL LEVER SURFACE ANGLE EQUAL DISPLAYED AT MCDU
POSITION INSTALLATION SYNCHRO ANGLE
PPU VALUE APPU FPPU IPPU
-------------------------------------------------------------------------------
Mech. Stop retr -2.81 deg 357.2 deg
0 0 deg 0 deg 0 deg
1 Auto 18 deg 222.77 deg 222.8 deg
1 Norm 18 deg 222.77 deg 222.8 deg
2 22 deg 272.27 deg 272.3 deg
3 22 deg 272.27 deg 272.3 deg
FULL 27 deg 334.16 deg 334.2 deg
Mech. Stop ext 336.97 deg 337.0 deg

NOTE: The APPUs must agree within 0.45 deg.
At position 0 the APPU/FPPU must agree within 0.9 deg.
At positions 1, 2, 3 and FULL, the APPU/FPPU must agree within 1.3 deg.
** ON A/C NOT FOR ALL
4. TABLE 4
A. WTB RESET Page
(1) When the SFCCμs have detected a critical system failure, application of the WTB is set to arrest the system/transmission in a fail- safe condition. Locked E/W is simultaneously triggered to inform the flight crew. The setting of the WTB is latched inside the SFCC (by means of latching relays keeping energized the WTB solenoid even if SFCC is not energized). The WTB reset function allows to reset the relays.
(2) When on the submenu pages SFCC-(1) (2) TEST/RESET the Line Key "1R" "WTB-RESET" is pressed, the named SFCC transmits the following page to the CFDS.
!\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\!
! SFCC- X !
! --- WTB=RESET !
1L ! CAUTION: XXXX WILL MOVE ! 1R
! ENSURE THAT SURFACE !
2L ! MOVEMENT IS POSSIBLE ! 2R
! WITHOUT DANGER TO !
3L ! PERSONNEL OR ! 3R
! AIRCRAFT OR !
4L ! MECHANICAL SYSTEM ! 4R
! !
5l ! < START WTB RESET ! 5R
! !
6l ! <RETURN PRINT> !
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

(3) In line 3 "CAUTION: XXXX WILL MOVE" the "XXXX" field is replaced with the the word FLAPS in the amber colour code.
(4) When on the WTB RESET instruction page the key 5L "START WTB RESET"is pressed.
(5) The related WTB relays in the SFCC are reset and the result is transmitted to the CFDS as
!\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\!
! SFCC- X !
! ---- WTB RESET !
1L ! ! 1R
! PERFORMED !
2L ! ! 2R
! !
3L ! ! 3R
! !
4L ! ! 4R
! !
5l ! ! 5R
! !
6l ! <RETURN PRINT> !
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

** ON A/C NOT FOR ALL
5. TABLE 5
A. SFCC SYSTEM DATA SLAT
(1) System Data submenu page
-------------------------------------
! SFCC 1 !
! SYSTEM DATA SLAT !
1L ### !<PPU X-LINK INPUT>! ### 1R
2L ### !<ARINC 429 INPUT STATUS ! ### 2R
3L ### !<DISCRETE INPUTS ! ### 3R
4L ### ! ! ### 4R
5L ### ! ! ### 5R
6L ### !<RETURN ! ### 6R
---------------------------------------

(2) Slat Arinc Input Status page
---------------------------------------
! SFCC-* !
! SLAT ARINC INPUT STATUS !
!ADIRU 1 OK (VIA FLP)!
!ADIRU 2 OK !
!CFDIU OK (VIA FLP)!
!WRAP AROUND OK !
! !
! !
! !
! !
!<RETURN PRINT>!
---------------------------------------

** ON A/C NOT FOR ALL
6. TABLE 6
A. SFCC MENU Selection
(1) Set MENU MODE
(a) Set CFDS
(b) Set SYSTEM REPORT TEST
(c) Set F/CTL
(d) Set SFCC 1 or SFCC 2. The page that follows is displayed.
--------------------------------------
! SFCC-* !
1L ### !<SLT LAST LEG REPORT FLP>! ### 1R
2L ### !<SLT PREV LEG REPORT FLP>! ### 2R
3L ### !<LRU IDENTIFICATION ! ### 3R
4L ### !<SLT SYSTEM STATUS FLP>! ### 4R
5L ### !<SLT CLASS 3 FAULTS FLP>! ### 5R
6L ### !<RETURN ! ### 6R
! !
---------------------------------------

(2) Set NEXT PAGE. The page that follows is displayed.
---------------------------------------
! SFCC-* !
1L ### !<SLT TEST/RESET FLP>! ### 1R
2L ### !<SLT SYSTEM DATA FLP>! ### 2R
3L ### !<SLT TROUB SH DATA FLP>! ### 3R
4L ### !<SLT ON GROUND FAULTS FLP>! ### 4R
5L ### ! ! ### 5R
6L ### !<RETURN ! ### 6R
! !
---------------------------------------

(3) Set TEST/RESET SLT>. The page that follows is displayed.
---------------------------------------
! SFCC-* !
! SLAT TEST/RESET !
1 ### !<SFCC TEST WTB-RESET>! ### 1R
2 ### !<WTB/POB TEST ! ### 2R
3 ### !<SFCC TEST FAILURE ! ### 3R
! REPORT (MEMORY READ OUT) !
4 ### ! ! ### 4R
5 ### ! ! ### 5R
6 ### ! ! ### 6R
-----------------------------------------

(4) Set <SFCC TEST. The page that follows is displayed.
-----------------------------------
! SFCC-* !
! SLAT SFCC TEST !
!IN PROGRESS !
! !
! !

(a) If the SFCC TEST is satisfactory, the page that follows is displayed.
----------------------------------
! SFCC-* !
! SLAT SFCC TEST !
!DATE:+++ ++ UTC: ++++ !
!NO FAULTS !
If the X computer arm test is not done during the test, this message shows:
!OTHER SFCC ARM SIGNAL !
!NOT TESTED !
! !
------------------------------------

(5) If the SFCC TEST finds the SFCC at fault the SFCC TEST results page is displayed as follows.
-----------------------------------------
! SFCC-* !
! SLAT SFCC TEST !
1L ### !DATE:+++ ++ UTC: (time) ! ### 1R
!PERFORMED WITH FAULT !
2L ### !<FAULT DATA ! ### 2R
3L ### ! ! ### 3R
4L ### ! ! ### 4R
5L ### ! ! ### 5R
6L ### !<RETURN ! ### 6R
-----------------------------------------

(6) Set FAULT DATA. The page that follows is displayed (valid for SFCC manufactured by BAE Systems).
-----------------------------------------
! SFCC-* !
! SLAT SFCC TEST !
!DATE:+++ ++ UTC: (time) !
!FAILURE DATA !
!LANE 1 : 0 0 0 0 0 0 !
!O/P L 1 : 0 0 0 0 0 0 0 0 0 0 0 0 !
!C/S L 2 : 0 0 !
!IP : 0 0 0 0 0 0 0 0 0 0 0 0 !
!LANE 2 : 0 0 0 0 0 0 !
!O/P L 2 : 0 0 0 0 0 0 0 0 0 0 0 0 !
!C/S L2 : 0 0 !
!ARINC : 0 0 0 0 0 0 0 0 0 0 0 0 !
!<RETURN PRINT>!
-----------------------------------------

NOTE: BITE TEST result decoding require Airbus or SFCC manufacturer assistance unless guidance are contained in the TSM 27-81-00 PB 201.
NOTE: LANE 1 is Lane 1 test
  • O/P L1 is Output test from lane 1
  • C/S L1 is Common services and PCU test from lane 1
  • I/P is Test of input discretes
    LANE 2 is Lane 2 test
  • O/P L2 is Output test from lane 2
  • C/S L2 is Common services and PCU test from lane 2
  • ARINC is Arinc test
(7) If the SFCC-TEST is done and the SFCC periphery is not complete, an SFCC-TEST result page is transmitted to the CFDS to indicate the status. SLAT or FLAP is added to the title.
----------------------------
! SFCC-* ->!
! SLAT SFCC TEST !
1L ###! DATE: UTC: !### 1R
! NO FAULTS BUT !
2L ###!* !### 2R
! !
3L ###!** !### 3R
! !
4L ###! !### 4R
! !
5L ###! !### 5R
! !
6L ###!<RETURN PRINT>!### 6R
----------------------------
SFCC test result page for SFCC periphery not complete, see Para (8).

(8) SFCC test result page for SFCC periphery not complete.
(a) "*" shows in case of X-computer arm test not being done during test, the message that follows is shown on line 5 and 6.
2L ###!OTHER SFSS ARM SIGNAL !
!NOT TESTED !

(b) "**" shows the peripheral faults or system messages that are not complete.
either !WTB SET !
and/or !NO WTB POWER !
and/or !LH WTB SOLENOID X/X !
and/or !RH WTB SOLENOID X/X !
and/or !FPPU FAULT !
and/or !LH APPU FAULT !
and/or !RH APPU FAULT !

NOTE: X/X shows short circuit (S/C) or open circuit (O/C).
(c) If more than one page is needed the "->" code is shown in the 24th character of line one of each SFCC test result page.
(d) The results of previous SFCC-TEST (automatic integrity test and maintenance SFCC test) can be shown with "SFCC TEST FAILURE REPORT" selected from the
TEST/RESET MENU key "3L".
(9) Set MENU MODE
(a) Set CFDS
(b) Set SYSTEM REPORT TEST
(c) Set F/CTL
(d) Set SFCC 1 or SFCC 2. The page that follows is displayed.
--------------------------------------
! SFCC-* !
1L ### !<SLT LAST LEG REPORT FLP>! ### 1R
2L ### !<SLT PREV LEG REPORT FLP>! ### 2R
3L ### !<LRU IDENTIFICATION ! ### 3R
4L ### !<SLT SYSTEM STATUS FLP>! ### 4R
5L ### !<SLT CLASS 3 FAULTS FLP>! ### 5R
6L ### !<RETURN ! ### 6R
! !
---------------------------------------

(10) Set NEXT PAGE. The page that follows is displayed.
---------------------------------------
! SFCC-* !
1L ### !<SLT TEST/RESET FLP>! ### 1R
2L ### !<SLT SYSTEM DATA FLP>! ### 2R
3L ### !<SLT TROUB SH DATA FLP>! ### 3R
4L ### !<SLT ON GROUND FAULTS FLP>! ### 4R
5L ### ! ! ### 5R
6L ### !<RETURN ! ### 6R
! !
---------------------------------------

(11) Set TEST/RESET SLT>. The page that follows is displayed.
---------------------------------------
! SFCC-* !
! SLAT TEST/RESET !
1 ### !<SFCC TEST WTB-RESET>! ### 1R
2 ### !<WTB/POB TEST ! ### 2R
3 ### !<SFCC TEST FAILURE ! ### 3R
! REPORT (MEMORY READ OUT) !
4 ### ! ! ### 4R
5 ### ! ! ### 5R
6 ### ! ! ### 6R
-----------------------------------------

(12) Set <SFCC TEST. The page that follows is displayed.
-----------------------------------
! SFCC-* !
! SLAT SFCC TEST !
!IN PROGRESS !
! !
! !

(a) If the SFCC TEST is satisfactory, the page that follows is displayed.
----------------------------------
! SFCC-* !
! SLAT SFCC TEST !
!DATE:+++ ++ UTC: ++++ !
!NO FAULTS !
If the X computer arm test is not done during the test, this message shows:
!OTHER SFCC ARM SIGNAL !
!NOT TESTED !
! !
------------------------------------

(13) If the SFCC TEST finds the SFCC at fault the SFCC TEST results page is displayed as follows.
-----------------------------------------
! SFCC-* !
! SLAT SFCC TEST !
1L ### !DATE:+++ ++ UTC: (time) ! ### 1R
!PERFORMED WITH FAULT !
2L ### !<FAULT DATA ! ### 2R
3L ### ! ! ### 3R
4L ### ! ! ### 4R
5L ### ! ! ### 5R
6L ### !<RETURN ! ### 6R
-----------------------------------------

(14) Set FAULT DATA. The page that follows is displayed (valid for SFCCs manufactured by Diehl).
----------------------------------
! SFCC-* !
! SLAT SFCC TEST !
! DATE: JAN 10 UTC: 1240 !
! FAILURE REPORT LANE A !
! X !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! !
!<RETURN PRINT>!
----------------------------------

----------------------------------
! SFCC-* !
! SLAT SFCC TEST !
! DATE: JAN 10 UTC: 1240 !
! FAILURE REPORT LANE B !
! X !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! 00 00 00 00 00 00 00 00 !
! !
!<RETURN PRINT>!
----------------------------------

NOTE: X can be PWR UP TEST or SFCC-TEST.
The available test result information of lane A/B is shown in a coded hexadecimal form.
Each lane indicates 48 bytes which are used to get information about each specific subtest.
(15) If the SFCC-TEST is done and the SFCC periphery is not complete, an SFCC-TEST result page is transmitted to the CFDS to indicate the status. SLAT or FLAP is added to the title.
----------------------------
! SFCC-* ->!
! SLAT SFCC TEST !
1L ###! DATE: UTC: !### 1R
! NO FAULTS BUT !
2L ###!* !### 2R
! !
3L ###!** !### 3R
! !
4L ###! !### 4R
! !
5L ###! !### 5R
! !
6L ###!<RETURN PRINT>!### 6R
----------------------------
SFCC test result page for SFCC periphery not complete, see Para (8).

(16) SFCC test result page for SFCC periphery not complete.
(a) "*" shows in case of X-computer arm test not being done during test, the message that follows is shown on line 5 and 6.
2L ###!OTHER SFSS ARM SIGNAL !
!NOT TESTED !

(b) "**" shows the peripheral faults or system messages that are not complete.
either !WTB SET !
and/or !NO WTB POWER !
and/or !LH WTB SOLENOID X/X !
and/or !RH WTB SOLENOID X/X !
and/or !FPPU FAULT !
and/or !LH APPU FAULT !
and/or !RH APPU FAULT !

NOTE: X/X shows short circuit (S/C) or open circuit (O/C).
(c) If more than one page is needed the "->" code is shown in the 24th character of line one of each SFCC test result page.
(d) The results of previous SFCC-TEST (automatic integrity test and maintenance SFCC test) can be shown with "SFCC TEST FAILURE REPORT" selected from the
TEST/RESET MENU key "3L".
** ON A/C NOT FOR ALL
7. TABLE 7
A. Table of Ground Circuits Supplied from SFCC 1 (Refence ASM/278110S01)
------------------------------------------------------------------------------
FIN FUNCTION DESIGNATION FLP POSITION
------------------------------------------------------------------------------
2CE1 ELAC 1 SAP 1 SLATS RETRACTED
101RH CIDS DIRECTOR SAP 3 SLATS >21'
1CC1 FAC 1 SAP 3 SLATS >21'
1CE1 SEC 1 SAP 3 SLATS >21'
2CE2 ELAC 2 SAP 4 SLATS RETRACTED
1CE2 SEC 2 SAP 5 SLATS >21'
102RH CIDS 2 DIRECTOR SAP 5 SLATS >21'
1CE3 SEC 3 SAP 5 SLATS >21'
44QA RELAY CTR TK PUMP 2 AUTO OFF SAP 6 SLATS >15'
43QA RELAY CTR TK PUMP 1 AUTO OFF SAP 6 SLATS >15'

B. Table of Ground Circuits Supplied from SFCC 2 (Refence ASM/278110S01)
------------------------------------------------------------------------------
FIN FUNCTION DESIGNATION FLP POSITION
------------------------------------------------------------------------------
2CE1 ELAC 1 SAP 1 SLATS RETRACTED
101RH CIDS DIRECTOR SAP 3 SLATS >21'
1CE1 SEC 1 SAP 3 SLATS >21'
2CE2 ELAC 2 SAP 4 SLATS RETRACTED
1CE2 SEC 2 SAP 5 SLATS >21'
1CC2 FAC 2 SAP 5 SLATS >21'
102RH CIDS 2 DIRECTOR SAP 5 SLATS >21'
1CE3 SEC 3 SAP 5 SLATS >21'
44QA RELAY CTR TK PUMP 2 AUTO OFF SAP 6 SLATS >15'
43QA RELAY CTR TK PUMP 1 AUTO OFF SAP 6 SLATS >15'

** ON A/C NOT FOR ALL
8. TABLE 8
A. SFCC Interactive MCDU Menu Management
(1) The structure of the SFCC interactive MCDU menu is as follows.
B. Several features/functions are essential to do the slat troubleshooting and to obtain data on fault identified by the system or status on the system:
(1) CFDS PAGES - SYSTEM STATUS
All maintenance messages (class 1, 2 and 3) related to all faults detected in real time by the system will be shown during the SYSTEM STATUS. In order to indicate a transient fault to the operator, the maintenance messages, automatically shown in SYSTEM STATUS, are only erased when exiting from the function.
CLASS 1
Faults which have an operational cockpit event. The status given by these faults are covered by the MMEL. Faults are present in the PFR.
CLASS 2
Faults which do not have consequence on the system operating conditions. Information of CLASS 2 faults is done through the ECAM MAINTENANCE STATUS. It is considered by repairing them before the next scheduled maintenance task, that the dispatch is significantly increased. CLASS 2 faults are shown in the PFR.
CLASS 3
Faults which have no consequence on the system operating conditions and the crew is not aware of them. Faults are not shown in the PFR but are available in the CLASS 3 FAULTS menu.
(2) CFDS PAGES - LAST LEG REPORT
This section presents all messages sent to the CFDIU. The SFCC does not make any correlation as opposed to CFDIU which determines the identifiers. This is a simplified backup of the printed PFR.
(3) CFDS PAGES - PREVIOUS LEGS REPORT
The previous legs report function is the history of the LAST LEG REPORT of the system limited to 64 flights.
(4) On ground fault
The MCDU displays the faults stored in the "on ground failure memory" (generally limited to the 3 last faults recorded). But if no failures are stored the MCDU shows the "NO FAULTS" message. This function shows on ground the class 1,2 and 3 maintenance messages related to new faults detected on ground and which are therefore not recorded in the PFR. The faults detected during flight and still present on ground are in the PFR/CLASS3 FAULTS and not in the ON GROUND FAULTS (except class 3 faults). This function presents the history of these faults since the aircraft landed up to the next take-off.
(5) CFDS PAGES - CLASS 3 FAULTS
All class 3 maintenance messages corresponding to the selected system are grouped under this section.
(6) SLAT SYSTEM DATA - PPU
The slat data is refreshed every 5 seconds with updated data. "272.3" represents the decimal value of the synchro angles. "C1A" represents the hexadecimal value of the same data.
C. System Tests
(1) WTB/POB Test
  • This test allows to check the engagement and performance of the WTB and POB. Please refer to AMM Task 27-81-00-710-001-A, Operational Test of the Wing Tip Brake and Pressure Off Brake.
(2) WTB RESET
  • Please refer to AMM Task 27-80-00-869-004-A, Reset of the Wing Tip Brake of the Slat System on the Ground.
(3) SFCC Test (please also refer to table 6)
  • Please refer to AMM Task 27-81-00-740-002-A, BITE Test of the SFCCs (Slat System).
D. Other features might help to further investigate a fault, but will only be used on case by case review and will require assistance of AIRBUS or SFCC manufacturer for interpretation.
(1) System Data > X-Link Input (please also refer to table 1)
(2) System Data > Discrete Input (please also refer to table 5)
(3) System Data > ARINC 429 Input Status (please also refer to table 5)
(4) SFFC Test Failure Report (please also refer to table 6)
E. Trouble Shooting Data
(1) The "TROUBLE SHOOTING DATA" item provides additional data about the failures (all classes) recorded during the last and previous legs. The adjacent to a message prompt gives access to the corresponding snapshot.