GND HF DATALINK pb-sw
| 23-01-04-01A | GND HF DATALINK pb-sw |
|---|
Applicable to: -
- Before Refuel, Defuel or Ground Fuel Transfer
- HF1 and HF2Set to VOICE mode
- HF1 and HF2Do not use until refuel is completed
| 23-01-04-01A | GND HF DATALINK pb-sw |
|---|
Applicable to: -
- Before Refuel, Defuel or Ground Fuel Transfer
- HF1Set to VOICE mode
- HF1Do not use until refuel is completed