Avionics Skin Air Inlet Valve (Air conditioning inlet valve open on the ground)
| 21-26-05A | Avionics Skin Air Inlet Valve (Air conditioning inlet valve open on the ground) |
|---|
Applicable to: -
- During cockpit preparation
Supply the aircraft electrical
network.
Check that the air conditioning
is operating with one or two air conditioning packs set to on.
- EXTRACT pb-swOVRD
Clear the VENT AVNCS SYS FAULT alert displayed on the EWD using the CLR pb.
| Note: | With only one air conditioning pack operative,
operating time on ground is limited to 1 h. |
- After takeoff
- EXTRACT pb-swAUTO
- After landing
- EXTRACT pb-swOVRD