W DOC AIRBUS | MMEL OPS PROC

Avionics Skin Air Inlet Valve (Air conditioning inlet valve open on the ground)


21-26-05AAvionics Skin Air Inlet Valve (Air conditioning inlet valve open on the ground)
Applicable to: -
- During cockpit preparation
Supply the aircraft electrical network.
Check that the air conditioning is operating with one or two air conditioning packs set to on.
  • EXTRACT pb-swOVRD
Clear the VENT AVNCS SYS FAULT alert displayed on the EWD using the CLR pb.
Note:
With only one air conditioning pack operative, operating time on ground is limited to 1 h.
- After takeoff
  • EXTRACT pb-swAUTO
- After landing
  • EXTRACT pb-swOVRD