Avionics Extract Fan (VENT AVNCS SYS FAULT Alert not displayed)
| 21-26-02A | Avionics Extract Fan (VENT AVNCS SYS FAULT Alert not displayed) |
|---|
Applicable to: -
- Flight preparation/limitations
Time limitation
on ground with electrical network supplied:
OAT (°C) | ≤ 38 | ≤ 45 | ≤ 55 |
|---|---|---|---|
| Max time | No limit | 3 h | 35 min |
- During cockpit preparation
Supply the aircraft electrical
network.
Check that the air conditioning
correctly operates with both air conditioning packs set
to on.
- EXTRACT pb-swOVRD
Clear the VENT EXTRACT FAULT alert using the CLR pb.
- AVNCS VENT/EXTC/FAN (123VU AE2) C/BPull
Check that the VENT AVNCS SYS FAULT alert is not displayed on
the EWD.
| Note: | If the
ground horn sounds:
The C/B must be closed again after first engine start If the ground horn sounds after landing
when engines are off, it can be silenced again. In this case, the ADIRS must be set to OFF before leaving the aircraft. |
| 21-26-02A | Avionics Extract Fan (VENT AVNCS SYS FAULT Alert not displayed) |
|---|
Applicable to: -
- Flight preparation/limitations
Time limitation
on ground with electrical network supplied:
OAT (°C) | ≤ 38 | ≤ 45 | ≤ 55 |
|---|---|---|---|
| Max time | No limit | 3 h | 35 min |
- During cockpit preparation
Supply the aircraft electrical
network.
Check that the air conditioning
correctly operates with both air conditioning packs set
to on.
- EXTRACT pb-swOVRD
Clear the VENT EXTRACT FAULT alert using the CLR pb.
- AVNCS VENT/EXTC/FAN (123VU AC4) C/BPull
Check that the VENT AVNCS SYS FAULT alert is not displayed on
the EWD.
| Note: | If the
ground horn sounds:
The C/B must be closed again after first engine start If the ground horn sounds after landing
when engines are off, it can be silenced again. In this case, the ADIRS must be set to OFF before leaving the aircraft. |