W DOC AIRBUS | MMEL OPS PROC

System Label Indication on the HYD


29-07-07ASystem Label Indication on the HYD
Applicable to: -
- During cockpit preparation
NOTE:
If the Yellow Electric Pump is not available:
  • Pressurize the Yellow Hydraulic System with:
    • A Ground cart, or with
    • The Yellow Engine 2 Pump with the Engine 2 running.
  • Replace any action on the YELLOW ELEC PUMP pb-sw by a similar action on the Ground Cart or on the YELLOW ENG 2 PUMP pb-sw in the following procedure.
  • YELLOW ELEC PUMP pb-swON
  • BLUE ELEC PUMP pb-swAUTO
  • BLUE PUMP OVRD pb-swON
  • PTU pb-swAUTO
Move the CAPT stick left or right.
On the F/CTL SD Page, check the pairs of spoilers movement.
  • YELLOW ELEC PUMP pb-swOff
  • BLUE PUMP OVRD pb-swOFF