W DOC AIRBUS | MMEL OPS PROC

Yellow System Electric Pump


29-24-01AYellow System Electric Pump
Applicable to: -
- On ground
If the pump continuously runs and does not stop when set to off:
  • DOORS/CARGO (T12 on 122 VU) C/BPull
If unsuccessful:
  • Y HYD/ELEC PUMP/NORM (AB 03 on 123 VU) C/BPull
  • Y HYD/ELEC/PUMP (AB 06 on 123 VU) C/BPull
Note:
  1. If the pump continuously runs on the ground, there is a potential overheat situation.
  2. The reset of the C/Bs must be limited to the time required to open or close the cargo doors.