Yellow System Electric Pump
| 29-24-01A | Yellow System Electric Pump |
|---|
Applicable to: -
- On ground
If the pump continuously runs and does not stop
when set to off:
- DOORS/CARGO (T12 on 122 VU) C/BPull
If unsuccessful:
- Y HYD/ELEC PUMP/NORM (AB 03 on 123 VU) C/BPull
- Y HYD/ELEC/PUMP (AB 06 on 123 VU) C/BPull
| Note: |
|