W DOC AIRBUS | MMEL OPS PROC

Blue System Electric Pump


29-10-03ABlue System Electric Pump
Applicable to: -
- During preliminary cockpit preparation
If the blue electric pump continuously runs:
At electrical power supply application:
  • BLUE ELEC PUMP pb-swOFF
- After engine start
  • BLUE ELEC PUMP pb-swAUTO
If the blue electric pump does not automatically start:
  • BLUE PUMP OVRD pb-swON
On the HYD SD Page, check that the blue hydraulic circuit pressure is available.
- After engine shutdown
  • BLUE ELEC PUMP pb-swOFF