ACT 1 Inlet Valve
| 28-28-09C | ACT 1 Inlet Valve |
|---|
Applicable to: -
- On ground or in flight
When there is less than 3000 kg ( 6700 lb) of fuel in the center tank:
Disregard and clear
the FUEL ACT XFR FAULT alert
displayed on the EWD.