Elevator Position Indication on the F/CTL
| 27-07-04A | Elevator Position Indication on the F/CTL |
|---|
Applicable to: -
- During cockpit preparation
NOTE:
If the Yellow Electric
Pump is not available:
- Pressurize the Yellow Hydraulic System with:
- A Ground cart, or with
- The Yellow Engine 2 Pump with the Engine 2 running.
- Replace any action on the YELLOW ELEC PUMP pb-sw by a similar action on the Ground Cart or on the YELLOW ENG 2 PUMP pb-sw in the following procedure.
Check of the elevator control:
- YELLOW ELEC PUMP pb-swON
- PTU pb-swAUTO
- BLUE ELEC PUMP pb-swAUTO
- BLUE PUMP OVRD pbON
Establish communication with
the ground crew.
Move the CAPT or
the F/O stick to the maximum nose down position.
Visually check that both elevators
move down.
Move the CAPT or
the F/O stick to the maximum nose up position.
Visually check that both elevators
move up.
Move the CAPT or
the F/O stick to the neutral position.
Visually check
that both elevators go back to the neutral position.
- YELLOW ELEC PUMP pb-swOff
- BLUE PUMP OVRD pb-swOff