SEC 1
| 27-94-01A | SEC 1 |
|---|
Applicable to: -
- Flight preparation/limitations
For performance penalties, Refer to OpsProc Spoilers 3 and 4
- During cockpit preparation
NOTE:
If the Yellow Electric Pump
is not available:
- Pressurize the Yellow Hydraulic System with:
- A Ground cart, or with
- The Yellow Engine 2 Pump with the Engine 2 running.
- Replace any action on the YELLOW ELEC PUMP pb-sw by a similar action on the Ground Cart or on the YELLOW ENG 2 PUMP pb-sw in the following procedure.
| Note: | After application of the maintenance
procedure, the C/B TRIPPED R ELEC BAY and the C/B TRIPPED ON OVHD PNL alerts are
displayed on the EWD. |
Check of
the elevator control and roll spoilers control through the operative
computers:
Put the aircraft in the test configuration:
- YELLOW ELEC PUMP pb-swON
- PTU pb-swAUTO
- BLUE ELEC PUMP pb-swAUTO
- BLUE PUMP OVRD pbON
- ELAC 1 pb-swOn
- ELAC 2 pb-swOn
- SEC 2 pb-swOn
- SEC 3 pb-swOn
Wait 5 s
Check of
the elevator control through the ELAC 1:
- BLUE PUMP OVRD pb-swOff
Wait for hydraulic circuit depressurization.
On the F/CTL SD Page, check that blue elevator actuator symbol becomes amber.
Wait 5 s
- BLUE PUMP OVRD pb-swON
- ELAC 2 pb-swOFF
- SEC 2 pb-swOFF
Move the CAPT stick
from forward stop to aft stop.
On the F/CTL SD Page, check the full travel of both elevators.
| CAUTION: | If an expected elevator
movement does not occur, do not attempt any reset. Contact the maintenance. |
Check of
the elevator control through the SEC 2:
- ELAC 2 pb-swOn
- SEC 2 pb-swOn
Wait 5 s
- YELLOW ELEC PUMP pb-swOff
Wait for hydraulic circuits
depressurization.
On the F/CTL SD Page, check that the yellow and the green elevator actuators symbols
become amber.
Wait 5 s
- YELLOW ELEC PUMP pb-swON
- ELAC 1 pb-swOFF
- ELAC 2 pb-swOFF
Move the CAPT stick
from right stop to left stop, then from forward stop to aft stop.
Each stop must be
applied during 3 s
On the F/CTL SD Page, check the correct movement of the pairs of spoilers 2 and 5 and
the full travel of both elevators.
Move the F/O stick
from right stop to left stop, then from forward stop to aft stop.
Each stop must be
applied during 3 s
On the F/CTL SD Page, check the correct movement of the pairs of spoilers 2 and 5 and
the full travel of both elevators.
| CAUTION: | If an expected spoiler
or elevator movement does not occur, do not attempt any reset. Contact the maintenance. |
Return to
normal configuration:
- YELLOW ELEC PUMP pb-swOff
- BLUE PUMP OVRD pb-swOff
- ELAC 1 pb-swOn
- ELAC 2 pb-swOn
- SEC 1 pb-swOff
Check that
the DC TIE contactor 1 is closed:
Supply the electrical network
from the APU or the external power.
On the ELEC SD Page, check the link between the DC BUS 1 and the DC BAT BUS.
- In flight
Do not use the speedbrakes.
If the SEC 2 and the SEC 3 fail during
the flight:
Autoland
is not permitted.
Maximum
landing capability is CAT 1
Disengage the AP at 500 ft RA before landing in direct law.
When the AP is disengaged with the three SECs failed, it cannot be
engaged again.