AFT Cargo Isolation Valve (Valves checked closed)
| 21-28-04A | AFT Cargo Isolation Valve (Valves checked closed) |
|---|
Applicable to: -
- Flight preparation/limitations
The (If Installed) AFT Cargo
Heating and the ventilation in the AFT cargo compartment
are not available.
Ensure that the AFT cargo compartment
does not contain materials sensitive to important temperature variations
or sensitive to the lack of ventilation.
In that respect, for live animal transportation,
use the Live Animal Transportation Calculation Tool.
- During cockpit preparation
- ANN LT selectorTEST
Check that the AFT ISOL
VALVE pb-sw FAULT light comes on.
- ANN LT selectorBRT or DIM
- AFT ISOL VALVE pb-swOFF
Check that the AFT ISOL
VALVE pb-sw FAULT light does not come on.
If the AFT ISOL VALVE pb-sw FAULT light comes
on:
The AFT cargo isolation valves must be
secured in the closed position. Refer to Item 21-28-04B AFT Cargo Isolation Valve
Disregard the COND AFT CRG ISOL VALVE alert displayed on the EWD.