W DOC AIRBUS | MMEL OPS PROC

Avionics Skin Air Outlet Valve


21-26-04AAvionics Skin Air Outlet Valve
Applicable to: -
- On ground
After application of the maintenance procedure:
Clear the VENT AVNCS SYS FAULT alert displayed on the EWD using the CLR pb.
The VENT AVNCS SYS FAULT alert will be displayed after landing.
Note:
Avionics smoke may be not perceptible from the cockpit due to the opening of the internal flap of the valve.
In the case of AVIONICS SMOKE alert:
Apply the ECAM procedure even if the smoke is not perceptible.