Avionics Skin Air Outlet Valve
| 21-26-04A | Avionics Skin Air Outlet Valve |
|---|
Applicable to: -
- On ground
After application of the maintenance procedure:
Clear the VENT AVNCS SYS FAULT alert displayed on the EWD using the CLR pb.
The VENT AVNCS SYS FAULT alert will be displayed after
landing.
| Note: | Avionics
smoke may be not perceptible from the cockpit due to the opening of
the internal flap of the valve. In the
case of AVIONICS
SMOKE alert: Apply the ECAM procedure
even if the smoke is not perceptible. |