W DOC AIRBUS | MMEL OPS PROC

Lavatory and Galley Extraction Fan


21-23-01BLavatory and Galley Extraction Fan
Applicable to: -
- General Information
Two amber crosses replace the cabin zone temperature indications on the COND SD Page.
The INOP SYS column on the STATUS SD Page may display the LAV DET message.
The cabin zone temperature regulation is lost.
The Zone Controller commands fixed FWD and AFT cabin ducts temperature (set to 15 °C or 59 °F).
To recover the cockpit temperature regulation:
  • HOT AIR pb-swOFF
To control cockpit temperature, use the COCKPIT selector on the AIR COND overhead panel.
21-23-01BLavatory and Galley Extraction Fan
Applicable to: -
- General Information
Two amber crosses replace the cabin zone temperature indications on the COND SD Page.
The INOP SYS column on the STATUS SD Page may display the LAV DET message.
The cabin zone temperature regulation is lost.
The Air Conditioning System Controller commands FWD and AFT cabin ducts temperature using the position of the FWD CABIN selector and the AFT CABIN selector on the AIR COND overhead panel.
Slight effect on cabin comfort may occur.
The cockpit temperature regulation is still operative.