Start Valve
| 80-11-01A | Start Valve |
|---|
Applicable to: -
- Before engine start
- In Flight
If the affected engine shuts
down, attempt to restart it only using windmilling relight.
| 80-11-01A | Start Valve |
|---|
Applicable to: -
- Before engine start
The following
table gives the minimum time after engine shutdown before to manual
override the Start Valve.
Airport
Elevation (ft) | Minimum Engine Shutdown
Time (h) * |
|---|---|
4000 and below | 9 |
4001 to 5000 above Sea Level | 9.5 |
5001 to 10000 above Sea Level | 10 |
Greater than 10000 above Sea Level | 10.5 |
These times apply only for engines
that have performed normal flight operations and have followed the
recommended 3 min idle cooldown prior
to shutdown. If not operated in this manner, 12 h must
be observed.
- In Flight
If the affected engine shuts
down, attempt to restart it only using windmilling relight.