W DOC AIRBUS | MMEL OPS PROC

Start Valve


80-11-01AStart Valve
Applicable to: -
- Before engine start
- In Flight
If the affected engine shuts down, attempt to restart it only using windmilling relight.
80-11-01AStart Valve
Applicable to: -
- Before engine start
The following table gives the minimum time after engine shutdown before to manual override the Start Valve.
Airport Elevation (ft)
Minimum Engine Shutdown Time (h) *
4000 and below
9
4001 to 5000 above Sea Level
9.5
5001 to 10000 above Sea Level
10
Greater than 10000 above Sea Level
10.5
These times apply only for engines that have performed normal flight operations and have followed the recommended 3 min idle cooldown prior to shutdown. If not operated in this manner, 12 h must be observed.
- In Flight
If the affected engine shuts down, attempt to restart it only using windmilling relight.