AIR BLEED MAINTENANCE Message
| 36-00-01 | AIR BLEED MAINTENANCE Message |
|---|
Applicable to: -
36-00-01-A No fault on a BMC, on a pylon leak detection loop
or on the APU leak detection loop
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
(m)
AIR BLEED MAINTENANCE message may be displayed on the STATUS SD Page provided
that it is checked that the CFDS does not report any fault
on a BMC, on a pylon leak detection loop or on the APU leak detection loop.
36-00-01-B Only RH side affected
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
(m)
1)
2)
3)
AIR BLEED MAINTENANCE message may be displayed on the STATUS SD Page provided
that:
1)
The CFDS does not report any
fault on the BMC 1, on the LH pylon leak detection
loop or on the APU leak detection loop, and
2)
If the CFDS reports a fault
on the BMC 2, the BMC 2 is inoperative
3)
If the CFDS reports a fault
on the RH pylon leak detection loop, the RH pylon
leak detection loop is inoperative.
36-00-01-C Only LH side and/or APU leak detection
loop affected
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
(m)
1)
2)
3)
4)
AIR BLEED MAINTENANCE message may be displayed on the STATUS SD Page provided
that:
1)
The CFDS does not report any
fault on the BMC 2 or on the RH pylon leak detection
loop, and
2)
If the CFDS reports a fault
on the BMC 1, the BMC 1 is inoperative
3)
If the CFDS reports a fault
on the LH pylon leak detection loop, the LH pylon
leak detection loop is inoperative
4)
If the CFDS reports a fault
on the APU leak detection loop, the APU leak
detection loop is inoperative.
| 36-00-01 | AIR BLEED MAINTENANCE Message |
|---|
Applicable to: -
36-00-01-D No fault on the APU leak detection
loop
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
(m)
AIR BLEED MAINTENANCE message may be displayed on the STATUS SD Page provided that it is checked that the CFDS does
not report any fault on the APU leak detection
loop.
36-00-01-E APU leak detection loop affected
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
AIR BLEED MAINTENANCE message may be displayed on the STATUS SD Page provided
that the APU leak detection loop is considered inoperative.
| 36-00-01 | AIR BLEED MAINTENANCE Message |
|---|
Applicable to: -
36-00-01-F
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
AIR BLEED MAINTENANCE message
may be displayed on the STATUS SD Page.