W DOC AIRBUS | MMEL ITEMS A320F

ELEC IDG 1(2) FILTER CLOG Alert


24-09-04ELEC IDG 1(2) FILTER CLOG Alert
Applicable to: -
24-09-04-A False alert
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
(m)
One may be displayed on the EWD provided that:

1)
The sight glass of the affected IDG shows a correct oil level, and

2)
The Differential Pressure Indicator (DPI) of the oil filter is not extended on the affected IDG.

24-09-04-B Actual alert with generator set to OFF
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
(o)
One may be displayed on the EWD provided that the associated generator is set to OFF and considered as inoperative.

24-09-04-C Actual alert
Repair intervalNbr installedNbr requiredPlacard
A 21No
One may be displayed on the EWD for 15 flight hours or one flight day, whichever occurs first.