ELEC IDG 1(2) FILTER CLOG Alert
| 24-09-04 | ELEC IDG 1(2) FILTER CLOG Alert |
|---|
Applicable to: -
24-09-04-A False alert
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 1 | No |
(m)
1)
2)
One may be displayed on the EWD provided that:
1)
The sight glass of the affected IDG shows a correct oil level, and
2)
The Differential Pressure Indicator (DPI) of the oil filter is not extended on the affected IDG.
24-09-04-B Actual alert with generator set to OFF
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 1 | No |
(o)
One may
be displayed on the EWD provided that the associated generator
is set to OFF and considered as inoperative.
24-09-04-C Actual alert
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 2 | 1 | No |
One may be displayed on the EWD for 15 flight hours or one flight day, whichever occurs first.