ELEC IDG 1(2) OIL LO LVL Alert
| 24-09-03 | ELEC IDG 1(2) OIL LO LVL Alert |
|---|
Applicable to: -
24-09-03-A False alert
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 1 | No |
(m)
1)
2)
One may be displayed on the EWD provided that:
1)
The sight glass of the affected IDG shows a correct oil level, and
2)
The Differential Pressure Indicator (DPI) of the oil filter is not extended on the affected IDG.
24-09-03-B Actual alert with generator set to OFF
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 1 | No |
(o)
One may
be displayed on the EWD provided that the associated generator
is set to OFF and considered as inoperative.
24-09-03-C Actual alert
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 2 | 1 | No |
One may be displayed on the EWD for 15 flight hours or one flight day, whichever occurs first.
24-09-03-D Actual alert with evidence of IDG oil leakage
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 1 | No |
(o)(m)
1)
2)
3)
4)
One may be displayed on the EWD provided that:
1)
The associated IDG is disconnected,
and
2)
The associated IDG is completely
drained, and
3)
The associated AC main generation
is considered inoperative, and
4)
The wing tank fuel temperature on the affected side is checked to
be above -39 °C before engine start.