W DOC AIRBUS | MMEL ITEMS A320F

Engine Bleed HP Valve


36-11-07Engine Bleed HP Valve
Applicable to: -
36-11-07-A Associated bleed considered inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
One may be inoperative in the closed position provided that the associated engine bleed air supply system is considered inoperative.

36-11-07-B HP valve secured in the closed position
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
(o)(m)
One may be inoperative provided that:

1)
The affected engine bleed HP valve is secured in the closed position, and

2)
The opposite engine bleed supply system is operative.