CDLS Door Release Strike (Catch, Spring, Solenoid, Bolt)
| 52-51-06 | CDLS Door Release Strike (Catch, Spring, Solenoid, Bolt) |
|---|
Applicable to: -
52-51-06-A One inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| D 01.08.2026 | 3 | 2 | No |
(m)
One may be inoperative.
NOTE:
Apply the maintenance procedure
only when the inoperative door release strike is failed in the locked
position. If the center release strike is deactivated, the cockpit
door OPEN light is considered inoperative.
52-51-06-B Two or more inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| B 06.04.2026 | 3 | 0 | No |
(m)
Two or more may be inoperative provided that the CDLS Normal
System and the (If Installed) BK UP System are considered
inoperative.
NOTE:
Apply the maintenance
procedure only when the inoperative door release strikes are failed
in the locked position.