W DOC AIRBUS | MMEL ITEMS A320F

Galley Oxygen Unit


35-20-04Galley Oxygen Unit
Applicable to: -
NOTE:
For an inoperative cabin attendant oxygen unit located within the galley area:
35-20-04-A Adjacent cabin attendant oxygen unit available
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
-0Yes
(o)
One or more may be inoperative and the associated galley area may be occupied provided that an adjacent cabin attendant individual oxygen unit is available for each occupants of the associated galley area.

35-20-04-B Portable oxygen available in the associated galley area
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
-0Yes
(o)
One or more may be inoperative and the associated galley area may be occupied provided that a cabin attendant portable oxygen device is available for each occupants of the associated galley area.

35-20-04-C Altitude limited according to regulations
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
-0Yes
One or more may be inoperative and the associated galley area may be occupied provided that the operating altitude is limited according to regulations.

35-20-04-D Associated galley area not occupied
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
-0Yes
One or more may be inoperative provided that the associated galley area is not occupied.