Cabin Attendant Oxygen Unit
| 35-20-02 | Cabin Attendant Oxygen Unit |
|---|
Applicable to: -
35-20-02-A Associated seats considered inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | - | - | No |
One or more may be inoperative provided that the associated seats
are considered inoperative.
35-20-02-B FL limitation
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | 0 | Yes |
(o)
1)
2)
3)
One or
more may be inoperative and the associated seats may
be occupied provided that:
1)
The operating altitude is limited to 250 FL, and
2)
The minimum operating altitude is in accordance with applicable operating
regulations, and
3)
Portable oxygen units (supplemental oxygen) are provided in accordance
with applicable regulations.