MANUAL Control of the MASK MAN ON
| 35-01-01-31 | MANUAL Control of the MASK MAN ON pb |
|---|
Applicable to: -
35-01-01-31-A AUTO control function checked operative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(m)
May be inoperative provided that the AUTO control function is checked
operative.
35-01-01-31-B FL limitation
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(o)
1)
2)
3)
May be inoperative provided
that:
1)
The operating altitude is limited to 250 FL, and
2)
The minimum operating altitude is in accordance with applicable operating
regulations, and
3)
The portable oxygen units (supplemental oxygen) are provided in accordance
with applicable regulations.