DOOR PRESS LOW Message on the Programming and Test Panel (PTP) STATUS Page
| 52-10-06 | (If Installed) DOOR PRESS LOW Message on the Programming and Test Panel (PTP) STATUS Page |
|---|
Applicable to: -
52-10-06-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| D 01.08.2026 | 4 | 0 | No |
(m)
One or more messages may be displayed
provided that the door bottle pressure is checked on the associated
bottle pressure gauge before the first MMEL dispatch and
then every 8 days.
| 52-10-06 | (If Installed) DOOR PRESS LOW Message on the Programming and Test Panel (PTP) STATUS Page |
|---|
Applicable to: -
52-10-06-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| D 01.08.2026 | 8 | 0 | No |
(m)
One or more messages may be displayed
provided that the door bottle pressure is checked on the associated
bottle pressure gauge before the first MMEL dispatch and
then every 8 days.
| 52-10-06 | (If Installed) CHECK DOOR PRESSURE Message on the Flight Attendant Panel (FAP) |
|---|
Applicable to: -
52-10-06-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| D 01.08.2026 | 4 | 0 | No |
(m)
One or more messages may be displayed
provided that the door bottle pressure is checked on the associated
bottle pressure gauge before the first MMEL dispatch and
then every 8 days.
| 52-10-06 | (If Installed) CHECK DOOR PRESSURE Message on the Flight Attendant Panel (FAP) |
|---|
Applicable to: -
52-10-06-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| D 01.08.2026 | 8 | 0 | No |
(m)
One or more messages may be displayed provided that the door bottle
pressure is checked on the associated bottle pressure gauge before
the first MMEL dispatch and then every 8 days.