STRIKE (TOP, MID, BOT) LEDs on the CKPT DOOR CONT Overhead Panel


52-01-01-02STRIKE (TOP, MID, BOT) LEDs on the CKPT DOOR CONT Overhead Panel
Applicable to: -
52-01-01-02-A CKPT DOOR FAULT light operative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
30Yes
(o)
One or more may be inoperative provided that the CKPT DOOR FAULT light indicator on the center pedestal is checked operative.

52-01-01-02-B CKPT DOOR FAULT light inoperative
Repair intervalNbr installedNbr requiredPlacard
- 30Yes
One or more may be inoperative provided that the CDLS Normal System is considered inoperative.