Turbine Active Clearance Control Valve
| 75-24-01 | Turbine Active Clearance Control Valve |
|---|
Applicable to: -
75-24-01-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| B 06.04.2026 | 2 | 1 | No |
(o)
One may be inoperative in the
closed position provided that the associated engine takeoff EGT margin is above 16 °C.