W DOC AIRBUS | MMEL ITEMS A320F

Oil Pressure Indication and Advisory on the ENGINE


79-07-02Oil Pressure Indication and Advisory on the ENGINE SD Page
Applicable to: -
NOTE:
Simultaneous illumination of the BLUE ELEC PUMP pb-sw FAULT light and the ENG 1(2) PUMP pb-sw FAULT light with engines off may be due to a failed engine oil low pressure switch. In this case, the ENG 1(2) OIL LO PR alert is inoperative.
79-07-02-C
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
One may be inoperative provided that:

1)
ETOPS is not conducted, and

2)
The associated ENG 1(2) OIL LO PR alert is operative, and

3)
The associated oil quantity indication is operative on the ENGINE SD Page.

79-07-02Oil Pressure Indication and Advisory on the ENGINE SD Page
Applicable to: -
NOTE:
Simultaneous illumination of the BLUE ELEC PUMP pb-sw FAULT light and the ENG 1(2) PUMP pb-sw FAULT light with engines off may be due to a failed engine oil low pressure switch. In this case, the ENG 1(2) OIL LO PR alert is inoperative.
79-07-02-A Associated thrust reverser checked operative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
(m)
One may be inoperative provided that:

1)
ETOPS is not conducted, and

2)
The associated ENG 1(2) OIL LO PR alert is operative, and

3)
The associated oil quantity indication is operative on the ENGINE SD Page, and

4)
The associated thrust reverser is checked operative.

79-07-02-B Associated thrust reverser considered inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
One may be inoperative provided that:

1)
ETOPS is not conducted, and

2)
The associated ENG 1(2) OIL LO PR alert is operative, and

3)
The associated oil quantity indication is operative on the ENGINE SD Page, and

4)
The associated thrust reverser is considered inoperative.

79-07-02Oil Pressure Indication and Advisory on the ENGINE SD Page
Applicable to: -
NOTE:
Simultaneous illumination of the BLUE ELEC PUMP pb-sw FAULT light and the ENG 1(2) PUMP pb-sw FAULT light with engines off may be due to a failed engine oil low pressure switch. In this case, the ENG 1(2) OIL LO PR alert is inoperative and the dispatch is not permitted.
79-07-02-C
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
One may be inoperative provided that:

1)
ETOPS is not conducted, and

2)
The associated ENG 1(2) OIL LO PR alert is operative, and

3)
The associated oil quantity indication is operative on the ENGINE SD Page.