F/O Total Air Temperature (TAT) Sensor Element Connected to the ADR 2
| 34-11-04 | F/O Total Air Temperature (TAT) Sensor Element Connected to the ADR 2 |
|---|
Applicable to: -
34-11-04-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | No |
(o)
1)
2)
3)
4)
May be
inoperative provided that:
1)
Both CAPT TAT sensor
elements are operative, and
2)
The ADR 1 and the ADR 3 are operative, and
3)
The TAT indication on the SD is checked operative, and
4)
The TAS indications on the ND 2 is considered inoperative.
| 34-11-04 | F/O Total Air Temperature (TAT) Sensor Element Connected to the ADR 2 |
|---|
Applicable to: -
34-11-04-B
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 1 | 1 | No |
Must be operative.