CAPT Total Air Temperature (TAT) Sensor Element Connected to the ADR 3


34-11-03CAPT Total Air Temperature (TAT) Sensor Element Connected to the ADR 3
Applicable to: -
34-11-03-A
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
10No
(o)
May be inoperative provided that:

1)
The CAPT sensor element connected to the ADR 1 is operative, and

2)
The F/O sensor connected to the ADR 2 is operative, and

3)
The ADR 1 and the ADR 2 are operative, and

4)
The TAT indication on the SD is checked operative.