CAPT Total Air Temperature (TAT) Sensor Element Connected to the ADR 3
| 34-11-03 | CAPT Total Air Temperature (TAT) Sensor Element Connected to the ADR 3 |
|---|
Applicable to: -
34-11-03-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | No |
(o)
1)
2)
3)
4)
May be
inoperative provided that:
1)
The CAPT sensor element connected
to the ADR 1 is operative, and
2)
The F/O sensor connected to
the ADR 2 is operative, and
3)
The ADR 1 and the ADR 2 are operative, and
4)
The TAT indication on the SD is checked operative.