Overwing Emergency Exit Slide or Slide Raft
| 25-62-02 | Overwing Emergency Exit Slide or Slide Raft |
|---|
Applicable to: -
25-62-02-A Slide inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 2 | - | No |
One or both may be inoperative provided
that the associated overwing emergency exit is considered inoperative.
NOTE:
When an overwing escape slide
is inoperative, both emergency exits on the same side are considered
inoperative.
25-62-02-B Slide removed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 2 | - | No |
(m)
One or both may be removed provided that
the associated overwing emergency exit is considered inoperative.
NOTE:
When an overwing escape slide
is inoperative, both emergency exits on the same side are considered
inoperative.
| 25-62-02 | Overwing Emergency Exit Slide or Slide Raft |
|---|
Applicable to: -
25-62-02-A Slide inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 2 | - | No |
One or both may be inoperative provided
that the associated overwing emergency exit is considered inoperative.
25-62-02-B Slide removed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 2 | - | No |
(m)
One or both may be removed provided that
the associated overwing emergency exit is considered inoperative.