Galley Waste Compartment Flapper Door
| 25-35-01 | (If Installed) Galley Waste Compartment Flapper Door |
|---|
Applicable to: -
25-35-01-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | 0 | No |
(o)(m)
1)
2)
One or more may be inoperative or missing
provided that:
1)
The galley waste compartment is empty, and
2)
The associated access is secured in the
closed position to prevent waste introduction.
NOTE:
Non-safety related galley equipment
is not listed in this MMEL.
+ Reference