APU Fire Extinguisher Overpressure Indication (Red Disc)
| 26-22-02 | APU Fire Extinguisher Overpressure Indication (Red Disc) |
|---|
Applicable to: -
26-22-02-A APU Fire extinguisher bottle pressure switch operative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | No |
(m)
May be damaged or missing provided that
the APU fire extinguisher bottle pressure switch is checked
operative before the first flight of each day.
26-22-02-B APU deactivated
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
May be inoperative provided that the APU is
deactivated.