APU Automatic Fire Extinguishing Control on Ground
| 26-22-01 | APU Automatic Fire Extinguishing Control on Ground |
|---|
Applicable to: -
26-22-01-A APU operations on ground monitored
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | No |
May be inoperative provided that the APU condition is continuously monitored in the cockpit during APU operations on ground .
26-22-01-B APU deactivated
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
May be inoperative provided that the APU is deactivated.