Smoke Detection Control Unit (SDCU)
| 26-17-02 | Smoke Detection Control Unit (SDCU) |
|---|
Applicable to: -
26-17-02-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | No |
May be inoperative provided that:
1)
The FWD, AFT, and BULK cargo compartments
are empty or do not contain flammable or combustible materials, and
2)
The lavatory smoke detection system is considered inoperative.
NOTE:
Failure of a single SDCU channel is indicated by a MAINTENANCE message
on the STATUS SD Page.
| 26-17-02 | Smoke Detection Control Unit (SDCU) |
|---|
Applicable to: -
26-17-02-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | No |
May be inoperative provided that:
1)
The FWD, AFT, and BULK cargo
smoke detection systems are considered inoperative, and
2)
The lavatory smoke detection system is considered inoperative.
NOTE:
Failure of a single SDCU channel is indicated by a MAINTENANCE message
on the STATUS SD Page.