W DOC AIRBUS | MMEL ITEMS A320F

AC Generation Indications on the ELEC


24-07-01AC Generation Indications on the ELEC SD Page
Applicable to: -
24-07-01-A
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
--No
(o)
One or more indications related to the AC generation may be inoperative provided that:

1)
The load, voltage, and frequency indications are operative on one engine driven generator , and

2)
The associated ELEC GEN 1(2) FAULT alert is operative, and

3)
The galley automatic load shed system is checked operative.