Battery Charger Limiter (BCL)
| 24-38-02 | Battery Charger Limiter (BCL) |
|---|
Applicable to: -
24-38-02-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 2 | 1 | No |
(o)(m)
1)
2)
3)
4)
5)
One may be inoperative for 10 flights provided that:
1)
ETOPS is not conducted, and
2)
No APU start is attempted
neither on ground nor in flight, and
3)
Both AC main generations are operative, and
4)
The refueling is made with an external
power unit connected, and
5)
The battery associated with the inoperative BCL is
charged before each flight.