W DOC AIRBUS | MMEL ITEMS A320F

AC ESS FEED FAULT


24-01-01-05AC ESS FEED pb-sw FAULT light
Applicable to: -
24-01-01-05-A
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
10Yes
May be inoperative provided that the AC ESS bus indication is operative on the ELEC SD Page.