W DOC AIRBUS | MMEL ITEMS A320F

Engine LP Fuel Valve Electrical Motor


28-24-01Engine LP Fuel Valve Electrical Motor
Applicable to: -
28-24-01-A
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
43No
(m)
One may be inoperative on one engine provided that:

1)
The affected motor is deactivated, and

2)
The remaining motor is checked operative.