LH Wing Transfer Valve
| 28-15-01 | LH Wing Transfer Valve |
|---|
Applicable to: -
28-15-01-A One or both inoperative open
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 0 | No |
(o)
One or
both may be inoperative in the open position.
28-15-01-B One or both inoperative with not usable fuel
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 0 | No |
(o)
One or
both may be inoperative in the closed position provided that the fuel
in the LH outer tank is considered as not usable and as
part of the ZFW.
28-15-01-C One inoperative closed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 1 | No |
(o)(m)
One may be inoperative in the closed
position provided that the remaining LH wing transfer valve
is secured in the open position after each refueling, or after each
aircraft repowering.