B(Y) ELEC PUMP FAULT
| 29-01-01-01 | B(Y) ELEC PUMP pb-sw FAULT light |
|---|
Applicable to: -
29-01-01-01-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 0 | Yes |
One or both may be inoperative provided
that the associated reservoir quantity indication is operative on
the HYD SD Page.
NOTE:
Simultaneous illumination
of the BLUE ELEC PUMP pb-sw FAULT light and the ENG 1(2) PUMP pb-sw FAULT light with engines off may be
due to a failed engine oil low pressure switch. In this case, the ENG 1(2) OIL LO PR alert is inoperative.
| 29-01-01-01 | B(Y) ELEC PUMP pb-sw FAULT light |
|---|
Applicable to: -
29-01-01-01-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 2 | 0 | Yes |
One or both may be inoperative provided that the associated reservoir
quantity indication is operative on the HYD SD Page.
NOTE:
Simultaneous illumination
of the BLUE ELEC PUMP pb-sw FAULT light and the ENG 1(2) PUMP pb-sw FAULT light with engines off may be
due to a failed engine oil low pressure switch. In this case, the ENG 1(2) OIL LO PR alert is inoperative
and the dispatch is not permitted.